Backup battery sizing & C&I storage payback estimate
Two free tools. Enter your own numbers and get a sizing recommendation plus a savings estimate. The results can be sent straight into an inquiry — our engineers reply with an accurate layout and quotation within 24 hours.
For home backup, emergency supply and off-grid systems. Works out the battery capacity and inverter size you need. See the UPS and storage backup sizing guide for the method.
Total power of equipment running at the same time
How long you need to stay running after an outage
Includes inverter and charging losses
Deeper discharge shortens cycle life
Send us these figures and we will come back with an accurate configuration and quotation.
Get an accurate proposalEstimates annual saving and static payback for a factory, warehouse or commercial park from your peak-valley tariff spread. Method and revenue model in the C&I storage revenue guide.
Tariff you avoid by discharging
Tariff you pay when charging
Usable charge / discharge energy
Equipment + installation + grid connection
Figures are in CNY; ask us for a USD quotation. Real output depends on local tariff policy, dispatch strategy and actual depth of discharge — we can run the precise calculation on your load curve.
Get an accurate calculationThe base formula is capacity (kWh) = load power (kW) × backup hours (h) ÷ system efficiency ÷ depth of discharge. For LFP just use 80% depth of discharge; in cold climates you still need extra derating. Lead-acid should stay at 50% or cycle life drops sharply.
Annual saving = daily dischargeable energy × peak-valley tariff spread × system efficiency × 365 days; static payback = total capex ÷ annual saving. That is an idealised figure — real output also depends on the length of the peak window, demand-charge management, tariff policy changes and your dispatch strategy.
Yes, and it is their biggest advantage over lead-acid. LFP is routinely discharged to 80% depth, giving roughly 1.6× the usable energy of lead-acid at the same nameplate capacity, with a far longer cycle life. That is why C&I projects overwhelmingly use LFP — see the battery lifespan and warranty guide for the numbers.
It is built for fast screening and early budgeting, so read the output as an order-of-magnitude reference. A precise design also needs the real load list, the 24-hour load curve, the short-circuit capacity at the connection point and the site temperature. NENGTUO runs that calculation free of charge — talk to our engineers.
Tell us the application and the capacity you need — professional quotation within 24 hours.